4.8.6.2 Repeat Count
Basic Definition | Description| | Example
Basic Definition
- Property Name
- REPEAT
- Purpose
- This property defines the number of time the alarm should be repeated, after the initial trigger.
- Value Type
- INTEGER
- Property Parameters
- Non-standard property parameters can be specified on this property.
- Conformance
- This property can be specified in a "VALARM" calendar component.
Description
If the alarm triggers more than once, then this property MUST be specified along with the "DURATION" property.
Format Definition
The property is defined by the following notation: repeatcnt = "REPEAT" repparam ":" integer CRLF ;Default is "0", zero. repparam = *(";" xparam)
Example
The following is an example of this property for an alarm that repeats 4 additional times with a 5 minute delay after the initial triggering of the alarm: REPEAT:4 DURATION:PT5M